You are here

Indoor Air

Project

Radon

Radon is a colourless, odourless gas released from the degradation of uranium naturally present in rock and soil. Radon levels outdoors are generally low; however, radon can enter buildings and homes through cracks and openings in the foundation and can accumulate at much higher concentrations indoors, especially in basements and lower floors. Over 3,200 Canadians are estimated to die each year...

View Full Article

Document

NCCEH Mould Investigation Toolkit

Public Health Inspectors (PHIs) and Environmental Health Officers (EHOs) across Canada have different responsibilities, policies, and guidelines when it comes to investigating public inquiries about mould in indoor environments. Some PHIs/EHOs conduct initial walkthroughs only, some conduct comprehensive investigations, and others educate the public about next steps without conducting any field...

View Full Article

Mould Assessment Recommendations - revised

Excessive dampness and mould growth on building material surfaces and contents can pose health risks and should not be tolerated in indoor environments. A mould assessment determines if mould is present, but does not determine or estimate mould exposure. Health-based exposure limits for indoor mould in residential environments have not been established; inspecting for visible and hidden mould,...

View Full Article

Mould Remediation Recommendations - revised

Excessive dampness and mould growth on building material surfaces and contents can pose health risks and should not be tolerated in indoor environments. The main goal of remediation is to reduce the risk of exposure to mould and to prevent structural damage; the underlying cause of dampness must be identified and eliminated or mould will reappear. Effective mould remediation requires the ...

View Full Article

Health Effects from Mould Exposure in Indoor Environments - revised

Moulds are naturally occurring and widespread in the environment; therefore, it is not possible to eliminate exposure. Sufficient evidence exists to conclude that exposure to mould in indoor environments is associated with asthma and asthma-like symptoms (in asthmatic people), upper respiratory tract symptoms, cough and wheeze, and hypersensitivity pneumonitis in susceptible people. There is...

View Full Article

Residential Use of Wood-Burning Appliances in Canada

This report summarizes information on woodsmoke emissions and health effects associated with woodsmoke exposures from residential wood-burning (RWB) in Canada and provides a qualitative indication of the potential effectiveness of different intervention strategies based on a review of the available literature and interviews with Canadian health authorities. The purpose of this report is to...

View Full Article

Effective Interventions to Reduce Indoor Radon Levels

Radon represents one of the environmental exposures that can be reduced with effective and practical solutions, reducing an individual’s risk of developing lung cancer. There is extensive literature supporting the cost-effectiveness of radon abatement compared with other healthcare and environmental interventions. Of the remediation measures evaluated to reduce indoor radon levels in already...

View Full Article

Residential Indoor Radon Testing

Radon is a known carcinogen, and is estimated to cause up to 10% of all lung cancers in Canada. It is a radioactive gas that is produced by the decay of uranium. Radon is naturally occurring, and emanates from soil and rocks. It percolates up through soil into buildings, and if it is not evacuated there can be much higher exposure levels indoors than outdoors. Fortunately, high radon levels can...

View Full Article

Guide for Implementing the Carbon Monoxide Monitoring and Response Framework in Long-term Care Facilities

This guide is intended for public health practitioners, facility/property maintenance managers, risk managers, occupational hygienists, clinicians, or other persons working at long-term care facilities (residential care facilities, nursing homes, seniors’ residences, care occupancies, etc.) who would like to implement a program to reduce the risk of indoor carbon monoxide (CO) exposure to...

View Full Article

Recommendations for Safe Re-occupancy of Marijuana Grow Operations

The following guide offers a practical approach to achieving safe re-occupancy of former marijuana grow operations (MGOs) and reviews possible exposures/hazards (tables 1 and 2). It is essential to make a clear distinction between risks associated with an “active” MGO and risks associated with a “shut down” MGO. An “active” MGO is linked to criminal activity, which in itself poses safety risks,...

View Full Article

Carbon Dioxide in Indoor Air

A Public Health Inspector calls about an issue flagged at an older elementary school.  As part of a teacher complaint process, the provincial health and safety agency has been conducting a workplace investigation.  Carbon dioxide (CO2) levels were measured and ranged from 412 ppm in an unoccupied classroom to 1,130 ppm in the school library and 1,660 ppm in an occupied classroom that had closed...

View Full Article

Pepper Spray in the Indoor Environment and in the Vicinity of Food Products and Preparation Surfaces

Pepper spray is discharged during an attempted robbery of a jewellery store in a large urban mall.  The robbery site is located next to the mall’s food court.  For several days, mall patrons continue to report uncomfortable symptoms (e.g., burning sensation in their eyes and throat) when they enter the food court.  Public Health Inspectors (PHIs) are asked to respond to concerns about...

View Full Article

Workshops Presentations

Event

UBC School of Population and Public Health - Characterizing the Impacts of Residential Woodsmoke in BC Communities

The best of current research in the Occupational and Environmental Hygiene (OEH) field is presented at these seminars, which run weekly during the academic year. Presenter: Matthew Wagstaff

View Full Article